AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > TERMINALS OF ECU |
| CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY |

Measure the voltage and resistance according to the value(s) in the table below.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| AIR (A16-22) - GND (A16-1) | L-W - L | Air inlet damper servo motor operation voltage | Ignition switch ON Fresh switch ON | Below 1 V |
| AIR (A16-22) - GND (A16-1) | L-W - L | Air inlet damper servo motor operation voltage | Ignition switch ON Recirculation switch ON | 11 to 14 V |
| AIF (A16-23) - GND (A16-1) | G-Y - L | Air inlet damper servo motor operation voltage | Ignition switch ON Recirculation switch ON | Below 1 V |
| AIF (A16-23) - GND (A16-1) | G-Y - L | Air inlet damper servo motor operation voltage | Ignition switch ON Fresh switch ON | 11 to 14 V |
| AOF (A16-3) - GND (A16-1) | Y-B - L | Air vent mode damper servo motor operation voltage | Ignition switch ON Mode switch DEF | Below 1 V |
| AOF (A16-3) - GND (A16-1) | Y-B - L | Air vent mode damper servo motor operation voltage | Ignition switch ON Mode switch FACE | 11 to 14 V |
| AOD (A16-4) - GND (A16-1) | R-B - L | Air vent mode damper servo motor operation voltage | Ignition switch ON Mode switch FACE | Below 1 V |
| AOD (A16-4) - GND (A16-1) | R-B - L | Air vent mode damper servo motor operation voltage | Ignition switch ON Mode switch DEF | 11 to 14 V |
| PIA (A15-17) - SG-7 (A15-21) | P-B - LG-R | Input signal for pulse position sensor (Air inlet damper servo motor) | Ignition switch ON Air inlet control: Changed from RECIRCULATION to FRESH or vice versa | Pulse generation |
| PIB (A15-16) - SG-7 (A15-21) | R-L - LG-R | Input signal for pulse position sensor (Air inlet damper servo motor) | Ignition switch ON Air inlet control: Changed from RECIRCULATION to FRESH or vice versa | Pulse generation |
| SG-7 (A15-21) - Body ground | LG-R - Body ground | Ground for pulse position sensor (Air inlet damper servo motor) | Always | Below 1 Ω |
| POA (A15-26) - SG-2 (A15-11) | L-O - L-Y | Input signal for pulse position sensor (Air vent mode damper servo motor) | Ignition switch ON Mode control: Changed from FACE to DEF or vice versa | Pulse generation |
| POB (A15-25) - SG-2 (A15-11) | LG - L-Y | Input signal for pulse position sensor (Air vent mode damper servo motor) | Ignition switch ON Mode control: Changed from FACE to DEF or vice versa | Pulse generation |
| SG-2 (A15-11) - Body ground | L-Y - Body ground | Ground for pulse position sensor (Air vent mode damper servo motor) | Always | Below 1 Ω |
| TE (A15-1) - SG-4 (A15-14) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature: 0°C (32°F) | 2 to 2.4 V |
| TE (A15-1) - SG-4 (A15-14) | G - P | A/C evaporator temperature sensor signal | Ignition switch ON Evaporator temperature: 15°C (59°F) | 1.4 to 1.8 V |
| SG-4 (A15-14) - Body ground | P - Body ground | Ground for A/C evaporator temperature sensor | Always | Below 1 Ω |
| IG+ (A16-6) - GND (A16-1) | R-L - L | Power source (IG) | Ignition switch off or ACC | Below 1 V |
| IG+ (A16-6) - GND (A16-1) | R-L - L | Power source (IG) | Ignition switch ON | 11 to 14 V |
| +B1 (A16-5) - GND (A16-1) | L-Y - L | Power source (Back-up) | Always | 11 to 14 V |
| GND (A16-1) - Body ground | L - Body ground | Ground for main power supply | Always | Below 1 Ω |
| BLW (A16-2) - GND (A16-1) | L-B - L | Blower motor speed control voltage | Ignition switch ON Blower switch ON (LO) | Pulse generation (see waveform 1) |
| TS (A15-7) - S5-3 (A15-2) | L-W - W-R | A/C solar sensor signal | Ignition switch ON | 0.8 to 4.3 V |
| S5-3 (A15-2) - GND (A16-1) | W-R - L | Power supply for solar sensor | Ignition switch ON | 4.5 to 5.5 V |
| HR (A16-14) - GND (A16-1) | L-W - L | HTR relay signal | Ignition switch ON Blower switch OFF | 11 to 14 V |
| HR (A16-14) - GND (A16-1) | L-W - L | HTR relay signal | Ignition switch ON Blower switch ON | Below 1 V |
| TR (A15-18) - SG-3 (A15-13) | GR - BR-Y | A/C room temperature sensor signal | Ignition switch ON Cabin temperature: 25°C (77°F) | 1.8 to 2.2 V |
| TR (A15-18) - SG-3 (A15-13) | GR - BR-Y | A/C room temperature sensor signal | Ignition switch ON Cabin temperature: 40°C (104°F) | 1.2 to 1.6 V |
| SG-3 (A15-13) - Body ground | BR-Y - Body ground | Ground for A/C room temperature sensor | Always | Below 1 Ω |
| RDFG (A16-12) - GND (A16-1) | R-L - L | Rear defogger switch signal | Ignition switch ON Rear defogger switch OFF | 11 to 14 V |
| RDFG (A16-12) - GND (A16-1) | R-L - L | Rear defogger switch signal | Ignition switch ON Rear defogger switch ON | Below 1 V |
| ACT (A16-7) - GND (A16-1) | R-L - L | Magnet clutch on permit input signal | Ignition switch START Magnet clutch ON: Not permitted | Below 1 V |
| ACT (A16-7) - GND (A16-1) | R-L - L | Magnet clutch on permit input signal | Ignition switch START Magnet clutch ON: Permitted | 11 to 14 V |
| AC1 (A16-21) - GND (A16-1) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch: Not engaged | 11 to 14 V |
| AC1 (A16-21) - GND (A16-1) | Y - L | Idle-up request signal | Ignition switch START Magnet clutch: Engaged | Below 1 V |
| SPD (A16-9) - GND (A16-1) | V-W - L | Vehicle speed signal | Driving at approx. 20 km/h (12 mph) | Pulse generation (see waveform 2) |
| PSW (A15-5) - GND (A16-1) | Y-B - L | Pressure switch signal | Ignition switch START Refrigerant pressure: Normal | Below 1 V |
| PSW (A15-5) - GND (A16-1) | Y-B - L | Pressure switch signal | Ignition switch START Refrigerant pressure: Less than 0.196 MPa (2.0 kgf/cm2, 28 psi) or more than 3.14 MPa (32.0 kgf/cm2, 455 psi) | 11 to 14 V |
| TAMO (A16-18) - GND (A16-1) | P - L | A/C ambient temperature signal | Ignition switch ON | Pulse generation |
| MGC (A16-13) - GND (A16-1) | B - L | Magnet clutch signal | Ignition switch START Magnet clutch: Not engaged | 11 to 14 V |
| MGC (A16-13) - GND (A16-1) | B - L | Magnet clutch signal | Ignition switch START Magnet clutch: Engaged | Below 1 V |
| SW1 (A16-16) - GND (A16-1) | G-O - L | Hazard warning switch signal | Hazard warning switch signal OFF | 11 to 14 V |
| SW1 (A16-16) - GND (A16-1) | G-O - L | Hazard warning switch signal | Hazard warning switch signal ON | Below 1 V |
| ILL+ (A16-15) - GND (A16-1) | G - L | Power supply for illumination | Light control switch OFF | Below 1 V |
| ILL+ (A16-15) - GND (A16-1) | G - L | Power supply for illumination | Light control switch TAIL | 11 to 14 V |
| AMC (A16-19) - GND (A16-1) | R-W - L | Air mix damper servo motor operation signal | Ignition switch ON Temperature switch Max. HOT | Below 1 V |
| AMC (A16-19) - GND (A16-1) | R-W - L | Air mix damper servo motor operation signal | Ignition switch ON Temperature switch Max. COOL | 11 to 14 V |
| AMH (A16-17) - GND (A16-1) | L - L | Air mix damper servo motor operation signal | Ignition switch ON Temperature switch Max. HOT | 11 to 14 V |
| AMH (A16-17) - GND (A16-1) | L - L | Air mix damper servo motor operation signal | Ignition switch ON Temperature switch Max. COOL | Below 1 V |
| PMA (A15-24) - SG-1 (A15-20) | W-R - BR-Y | Input signal for pulse position sensor (Air mix damper servo motor) | Ignition switch ON Temperature switch: Max. COOL → Max. HOT | Pulse generation |
| PMB (A15-23) - SG-1 (A15-20) | W-L - BR-Y | Input signal for pulse position sensor (Air mix damper servo motor) | Ignition switch ON Temperature switch: Max. HOT → Max. COOL | Pulse generation |
| SG-1 (A15-20) - Body ground | BR-Y - Body ground | Ground for pulse position sensor (Air mix damper servo motor) | Always | Below 1 V |
| TW (A16-8) - GND (A16-1) | P - L | Engine coolant temperature sensor signal | Ignition switch ON | Pulse generation |
![]() |
Using an oscilloscope, check waveform 1.
| Item | Content |
| Symbols (Terminal No.) | BLW (A16-2) - GND (A16-1) |
| Tool Setting | 1 V/DIV., 50 μsec./DIV. |
| Condition | Ignition switch ON, Blower switch ON (LO) |
![]() |
Using an oscilloscope, check waveform 2.
| Item | Content |
| Symbols (Terminal No.) | SPD (A16-9) - GND (A16-1) |
| Tool Setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Driving at approx. 20 km/h (12 mph) |
| CHECK ECM (for 1KD-FTV) |

Measure the voltage according to the value(s) in the table below.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| ACT (E5-19) - E1 (E6-7) | R-L - BR | Magnet clutch on permit output signal | Ignition switch START Magnet clutch ON: Not permitted | Below 1 V |
| ACT (E5-19) - E1 (E6-7) | R-L - BR | Magnet clutch on permit output signal | Ignition switch START Magnet clutch ON: Permitted | 11 to 14 V |
| AC1 (E5-18) - E1 (E6-7) | Y - BR | Idle-up request signal | Ignition switch START Magnet clutch: Engaged | Below 1 V |
| AC1 (E5-18) - E1 (E6-7) | Y - BR | Idle-up request signal | Ignition switch START Magnet clutch: Not engaged | 11 to 14 V |
| THW (E7-19) - E2 (E7-28) | R-L - BR | Engine coolant temperature sensor signal | Ignition switch START Engine coolant temperature 20°C (68°F) | 0.2 to 1.0 V |
| CHECK ECM (for 1GR-FE) |

Measure the voltage according to the value(s) in the table below.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| ACT (E13-25) - E1 (E17-1) | R-L - BR | Magnet clutch on permit output signal | Ignition switch ON Magnet clutch ON: Not permitted | Below 1 V |
| ACT (E13-25) - E1 (E17-1) | R-L - BR | Magnet clutch on permit output signal | Ignition switch ON Magnet clutch ON: Permitted | 11 to 14 V |
| AC1 (E13-24) - E1 (E17-1) | Y - BR | Idle-up request signal | Ignition switch ON Magnet clutch: Engaged | Below 1 V |
| AC1 (E13-24) - E1 (E17-1) | Y - BR | Idle-up request signal | Ignition switch ON Magnet clutch: Not engaged | 11 to 14 V |
| THW (E15-21) - E2 (E15-28) | B - BR | Engine coolant temperature sensor signal | Ignition switch START Engine coolant temperature 20°C (68°F) | 0.2 to 1.0 V |
| CHECK ACCESSORY METER ASSEMBLY |

Measure the voltage according to the value(s) in the table below.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| TH+ (A23-3) - SG (A23-2) | W-G - BR-Y | A/C ambient temperature sensor signal | Ignition switch ON Ambient temperature: 20 to 30°C (68 to 86°F) | 1 to 1.6 V |
| TH+ (A23-3) - SG (A23-2) | W-G - BR-Y | A/C ambient temperature sensor signal | Ignition switch ON Ambient temperature: 30 to 50°C (86 to 122°F) | 0.6 to 1 V |
| DATA (A23-9) - GND1 (A23-1) | P - LG | A/C ambient temperature sensor signal | Ignition switch ON | Pulse generation |
| CHECK COMBINATION METER ASSEMBLY |

Measure the voltage according to the value(s) in the table below.
| Symbols (Terminal No.) | Wiring Color | Terminal Description | Condition | Specified Condition |
| C10-6 - C10-22 | V-R - Y | Vehicle speed signal | Driving at approx. 20 km/h (12 mph) | Pulse generation |