FRONT DOOR LOCK > INSPECTION

for Preparation Click here



1. INSPECT FRONT DOOR LOCK ASSEMBLY RH


    B065429E15
  1. Apply battery voltage to the door lock and check the operation of the door lock motor.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 1
    Lock
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 4
    Unlock

    If the result is not as specified, replace the door lock assembly.



    B065430E13
  1. Measure the resistance of the door lock and unlock switch.

    Standard resistance:
    Tester Connection
    Door Lock Condition
    Specified Condition
    6 - 8
    Lock
    Below 1 Ω
    5 - 8, 6 - 8
    OFF
    10 kΩ or higher
    5 - 8
    Unlock
    Below 1 Ω

    If the result is not as specified, replace the door lock assembly.



2. INSPECT FRONT DOOR LOCK ASSEMBLY LH


    B065427E15
  1. Apply battery voltage to the door lock and check the operation of the door lock motor.

    OK:
    Measurement Condition
    Specified Condition
    Battery positive (+) → Terminal 4
    Battery negative (-) → Terminal 1
    Lock
    Battery positive (+) → Terminal 1
    Battery negative (-) → Terminal 4
    Unlock

    If the result is not as specified, replace the door lock assembly.



3. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (DOOR CONTROL SWITCH)


    B127495E02
  1. Measure the resistance of the door control switch.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    5 - 3
    Lock
    Below 1 Ω
    5 - 3, 8 - 3
    OFF
    10 kΩ or higher
    8 - 3
    Unlock
    Below 1 Ω

    If the result is not as specified, replace the power window regulator master switch assembly.